When a second hose clamp is installed on a small-bore fitting where the barb is not long enough, the clamp may be positioned only at the very end of the barb or even beyond it, which can crush or cut the barb, damage the inside of the hose, and do more harm than good—proper double clamping requires sufficient barb length.
causalpending
Speaker
Mike BonakerEvidence Quote
“especially on smaller hose sizes uh there's not enough room that the barb is not long enough to get two hose clamps on and by installing that second hose clamp which is either going to be just on the very end of the pipe to hose fitting the hose barb uh or may even be beyond it it's either gonna crush it”
Source
ABYC Online Education "Huddle": Discussion and Review of Popular Technical Topics with Mike Bonicker— American Boat & Yacht Council - ABYCCreated: 8/13/2026, 9:52:05 AM